Linea PlusHybrid

Warm power with a slimline design

Output more information
LineaPlusHybrid_Packshot

A Jaga classic with a discreet, slimline design with perforated grill and flat front panel, now upgraded with Hybrid technology for optimized output.

"Experience year-round comfort with a sleek, stylish convector that cools in summer and heats in winter. Designed with a focus on style and functionality for seamless integration into any modern space."

JAGA ACO (D09)

  • The fan speed is selected manually in 3 modes via the control panel.
  • When the water temperature is lower than 24°C and the air is warmer than the water in the heat exchanger, the fans will start. The unit will then cool the area.
  • When the water temperature is higher than 28°C and the air is colder than the water, the fans will start. The unit will then heat the area.
  • The unit will automatically switch from heating to cooling and to standby mode.

JAGA BMS 0-10V CONTROL (D03)

  • The fan speed is only controlled by a 0-10V (DC) signal via an external control system that is installed into the electronics of the unit. The 0-10V signal can come from a Jaga thermostat or another home automation or building management system.
  • When the control voltage is 1V or higher and the water temperature is higher than 28°C or lower than 24°C, the fans will start rotating. The rotational speed will increase proportionally with the configured control voltage. At 10V control voltage, the fans will rotate at maximum rotational speed.
  • When a Hybrid unit with Jaga BMS control is equipped with a thermoelectric valve motor connected to the internal electronics, the valve will open when the control voltage exceeds 1V.

JAGA TPT (D01)

  • The fan speed is automatically controlled in function of the preset comfort temperature via the fingertip controls. This allows the unit to be very silent once the comfort temperature is reached.
  • When a Hybrid unit with Jaga TPT control is equipped with a thermoelectric valve motor connected to the internal electronics, the unit will take over the function of room thermostat. Based on the room temperature measurement, the unit will then switch on or off the water flow through the unit itself.
  • If you wish to set the room temperature via another system that enables or disables the water flow through the unit, you do not need to connect a thermoelectric valve motor to the internal controller. The TPT controller will then only control the fan rotational speed based on the set comfort temperature. Intuitively, you will then use the fingertip control to get more or less fan support when the comfort temperature is reached.
  • When the water temperature in the heat exchanger is lower than 24°C, the fans will start. The unit will cool the area.
  • When the water temperature is higher than 28°C, the fans will start. The unit will heat the area.

 

Output

Linea Plus Hybrid

Height [cm] Length [cm] Type Position
wdt_ID wdt_created_by wdt_created_at wdt_last_edited_by wdt_last_edited_at Height [cm] Length [cm] Type Position Light Cooling (16/18/27°C) [Watts] Heating (35/30/20°C) [Watts] Heating (45/40/20°C) [Watts] Heating (50/45/20°C) [Watts] Heating (55/45/20°C) [Watts] Sound Pressure Level [dB(A)] Power consumption [Watts] Water Volume [l] Ordercode
1 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 50 11 1 148 190 366 457 499 26,0 3,6 3,0 LINW 035 050 11 XXX DDD
2 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 60 11 1 191 246 474 592 647 26,0 4,8 4,0 LINW 035 060 11 XXX DDD
3 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 70 11 1 234 301 580 724 791 26,0 5,5 5,0 LINW 035 070 11 XXX DDD
4 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 80 11 1 276 355 684 854 933 26,0 6,3 5,0 LINW 035 080 11 XXX DDD
5 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 90 11 1 317 408 786 982 1.072 26,0 6,7 6,0 LINW 035 090 11 XXX DDD
6 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 100 11 1 358 460 887 1.107 1.210 26,0 7,8 7,0 LINW 035 100 11 XXX DDD
7 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 110 11 1 401 516 995 1.242 1.357 26,0 8,4 7,0 LINW 035 110 11 XXX DDD
8 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 120 11 1 437 562 1.084 1.354 1.479 26,0 8,9 8,0 LINW 035 120 11 XXX DDD
9 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 140 11 1 515 662 1.277 1.595 1.743 26,0 10,1 9,0 LINW 035 140 11 XXX DDD
10 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 160 11 1 592 760 1.467 1.832 2.001 26,0 11,0 11,0 LINW 035 160 11 XXX DDD
11 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 180 11 1 675 867 1.673 2.090 2.283 26,0 12,2 12,0 LINW 035 180 11 XXX DDD
12 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 200 11 1 741 952 1.836 2.293 2.505 26,0 13,4 13,0 LINW 035 200 11 XXX DDD
13 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 220 11 1 809 1.040 2.005 2.505 2.736 26,0 13,4 15,0 LINW 035 220 11 XXX DDD
14 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 240 11 1 877 1.127 2.174 2.715 2.967 26,0 14,8 16,0 LINW 035 240 11 XXX DDD
15 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 260 11 1 950 1.220 2.353 2.939 3.211 26,0 16,2 17,0 LINW 035 260 11 XXX DDD
16 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 280 11 1 956 1.286 2.481 3.098 3.385 26,0 16,2 19,0 LINW 035 280 11 XXX DDD
17 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 50 11 2 158 203 391 489 555 30,0 4,1 7,0 LINW 035 050 11 XXX DDD
18 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 60 11 2 205 263 508 634 693 30,0 5,4 8,0 LINW 035 060 11 XXX DDD
19 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 70 11 2 251 322 622 777 849 30,0 5,9 9,0 LINW 035 070 11 XXX DDD
20 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 80 11 2 296 381 735 917 1.002 30,0 6,8 11,0 LINW 035 080 11 XXX DDD
21 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 90 11 2 341 438 846 1.056 1.154 30,0 7,4 12,0 LINW 035 090 11 XXX DDD
22 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 100 11 2 385 495 955 1.193 1.303 30,0 8,7 13,0 LINW 035 100 11 XXX DDD
23 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 110 11 2 432 556 1.072 1.339 1.462 30,0 9,3 15,0 LINW 035 110 11 XXX DDD
24 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 120 11 2 473 607 1.171 1.463 1.598 30,0 9,9 16,0 LINW 035 120 11 XXX DDD
25 jagadmin 16/04/2025 09:33 AM jagadmin 16/04/2025 09:33 AM 35 140 11 2 558 717 1.383 1.728 1.887 30,0 11,2 19,0 LINW 035 140 11 XXX DDD


Composition of the order code​​​

Hover over the parts below to find out what they stand for​​​​​

LINW 035 050 11 XXX DDD

Standard delivery

  • Low-H2O heat exchanger, with dirt and dust repellent coating in graphite grey (RAL 7024)
  • wall brackets and mounting set
  • angled air vent (standard and Height 020) or extended 1/8" air vent (twin) and 1/2" drain cock
  • partially assembled casing for a connection on the bottom left or bottom right
  • easy to install fan unit with operation, control and 24VDC power supply

This heater is not equipped with a condensation monitor. It has to be integrated into the installation (only for cooling).

Dimensions

LineaPlusHybrid_Dimensions